MC Glass Fire

  • a semi-structural facade system used to design fire-rated facade structures featuring the EI30, EI60 fire resistance
  • infill: Vetrotech glazing unit: 8 tempered /16 /25 Contraflam, internal fire-rated glass pane
  • fire-rated inserts in mullions and transoms: aluminium shaped sections filled with the Aestuver fire resistant cement compound supplied by Xella
  • transoms fixed to mullions using two ø6 pins and one ø10 pin (stainless steel); mullion and transom sockets are lined with intumescent tapes
  • the space between glasses is filled with an insulating material with thermal and fire-resistant features
  • in order to obtain a smooth external surface, the gap is filled with UV resistant silicone
VitraQ

Technical Specification

SYSTEM

MATERIAL

DEPTH OF MULLION


DEPTH OF TRANSOM

GLAZING RANGE

MULLIONS RIGIDITY

TRANSOM RIGIDITY

MCGF

aluminium

10-326 mm

10-294 mm

4-59 mm

from 2,5-4092 cm4*

from 0,9 la 1831,1*

Performance

SYSTEM

THERMAL INSULATION UF*

AIR PERMEABILITY

WINDLOAD RESISTANCE

WATER TIGHTNESS

MCGF

Uf from 0.88 W/m2K

Class AE1300; EN 12152

 2000 Pa – 3000 Pa; EN 13116 : 2004

Class RE1800; EN 12154